Technical Data
Technical Specifications
|
Weight |
115 g (4 oz) (device with battery and clip) |
||
|
Dimensions(L x W x D) |
87 x 55 x 48 mm (3.4 x 2.2 x 1.9 in) – with fastening clip |
||
|
Alarms |
Two super bright LEDs with 320° viewing angle and a loud audible alarm, vibrating alarm |
||
|
Volume of audible alarm |
95 dB typical at 30 cm distance |
||
|
Displays |
Large display of measured values |
||
|
Battery type |
Non-rechargeable Lithium battery, 3.6 Volts Only replace with: battery as listed in Replacement Parts and Accessories |
||
|
Battery life |
6 months to 18 months, depending on device settings, environmental conditions and general care and use. At very low and very high temperatures the useable battery runtime can be significantly reduced. Max current <50mA |
||
|
Sensor |
Electrochemical |
||
|
Warm up time |
1 minute during start-up procedure |
||
|
Temperature range |
Normal Operating Range |
-10°C to 40°C |
(14°F to 104°F) |
|
Extended Operating Range |
-20°C to 50°C |
(-4°F to 122°F) |
|
|
Short-term exposure (excluding the CO-HC sensor) |
-40°C to 60°C |
(-40°F to 140°F) |
|
|
Storage |
(32°F to 104°F) |
||
|
Vibrating Alarm |
(32°F to 122°F) |
||
|
Intrinsic Safety (ATEX, IEC, CSA) |
-40°C to 60°C |
(-40°F to 140°F) |
|
|
At extremely low temperatures (below -20°C), the display can have a very slow update rate and can become hard to read. |
|||
|
Atmospheric Pressure Range |
80 to 120 kPa |
(11.6 to 17.4 PSIA) |
|
|
Humidity range |
15 % to 90 % relative humidity, non-condensing |
||
|
5 % to 95 % relative humidity intermittent |
|||
|
Dust and spray protection |
IP 67 |
||