Technical Data

Technical Specifications

Weight

115 g (4 oz) (device with battery and clip)

Dimensions(L x W x D)

87 x 55 x 48 mm (3.4 x 2.2 x 1.9 in) – with fastening clip

Alarms

Two super bright LEDs with 320° viewing angle and a loud audible alarm, vibrating alarm

Volume of audible alarm

95 dB typical at 30 cm distance

Displays

Large display of measured values

Battery type

Non-rechargeable Lithium battery, 3.6 Volts

Only replace with: battery as listed in Replacement Parts and Accessories

Battery life

6 months to 18 months, depending on device settings, environmental conditions and general care and use.

At very low and very high temperatures the useable battery runtime can be significantly reduced.

Max current <50mA

Sensor

Electrochemical

Warm up time

1 minute during start-up procedure

Temperature range

Normal Operating Range

-10°C to 40°C

(14°F to 104°F)

Extended Operating Range

-20°C to 50°C

(-4°F to 122°F)

Short-term exposure (excluding the CO-HC sensor)

-40°C to 60°C

(-40°F to 140°F)

Storage

 

(32°F to 104°F)

Vibrating Alarm

 

(32°F to 122°F)

Intrinsic Safety (ATEX, IEC, CSA)

-40°C to 60°C

(-40°F to 140°F)

At extremely low temperatures (below -20°C), the display can have a very slow update rate and can become hard to read.

Atmospheric Pressure Range

80 to 120 kPa

(11.6 to 17.4 PSIA)

Humidity range

15 % to 90 % relative humidity, non-condensing

5 % to 95 % relative humidity intermittent

Dust and spray protection

IP 67