Factory-set Alarm Thresholds and Setpoints

Sensor

LOW alarm

HIGH alarm

STEL

TWA

LEL

10 % LEL

20 % LEL

--

--

O2 (%)

19.5

23.0

--

--

CO (ppm)

25

100

100

25

H2S (ppm)

10

15

15

10

Sensor

Min. alarm set point

Max. alarm set po

Auto-cal values

LEL

5 %

60 %

58 %

O2 (%)

5

24

15.0

CO (ppm)

10

1700

60

H2S (ppm)

5

175

20

Sensor LOW Alarm HIGH Alarm STEL TWA Min Alarm Setpoint Max Alarm Setpoint Auto-Cal Values
Ex 10% LEL 20% LEL -- -- 5 60 58%
EX-H 10% LEL 20% LEL -- -- 5 60 58%
EX-M 0.5 %vol 1.0 %vol -- -- 0.1%vol 3.0 %vol 2.5 %vol
H2S-LC 5 ppm 10 ppm 10 ppm 1 ppm 1 ppm 70 ppm 20 ppm
NO2 2 ppm 5 ppm 5 ppm 2 ppm 1 ppm 47.5 ppm 10 ppm
SO2 2 ppm 5 ppm 5 ppm 2 ppm 1 ppm 17.5ppm 10 ppm
O2 19.5% 23 % -- -- 5 24 15.0%
CO 25 ppm 100 ppm 100 25 10 1700 60 ppm
CO-H2 25 ppm 100 ppm 100 25 10 1700 60 ppm
H2S 10 ppm 15 ppm 15 10 5 175 20 ppm

NOTE: This device is not approved for use in atmospheres containing >21% oxygen.