Troubleshooting
Problem |
Description |
Reaction |
|
ERROR TEMP |
Temperature is below -40°C (-40°F) or above 75°C (167°F). |
Return device to normal Contact MSA |
|
ERROR EE |
EEPROM Memory error |
Contact MSA |
|
ERROR PRG |
Flash Memory error |
Contact MSA |
|
ERROR RAM |
RAM Memory error |
Contact MSA |
|
ERROR UNK |
Unknown error |
Contact MSA |
|
|
LOW BATT |
Battery warning repeats every 60 seconds. |
Remove from service as soon as possible and recharge battery |
|
BATT ALARM |
Battery is completely discharged. |
Device is no longer sensing gas. Remove from service and recharge battery. |
ERROR CHARGE |
Charge error |
Device must be between 10°C (50°F) and 36°C (97°F) to charge. Contact MSA if problem persists |
|
SENSOR ERROR |
Missing Sensor |
Verify if sensor is properly installed |
|
Device does not turn on |
Low battery |
Charge device |
|
|
Sensor warning |
Sensor is near the end of its life |
|
|
Sensor alarm |
Sensor has reached the end of its life and cannot be calibrated. Replace sensor and recalibrate. |