Technical Data

Weight

7.9 oz./224 g (device with battery and clip)

Dimensions

(L x W x H)

4.4 x 3.00 x 1.37 inches/112 x 76 x 33 mm
– without fastening clip

Alarms

Four gas alarm LEDs, a charge status LED, an audible alarm and a vibrating alarm

Volume of
audible alarm

95 dBA at 30 cm typical

Display

LCD display

Battery type

Rechargeable Li polymer battery.

Must not be charged in Ex area.

Device run time

(Bluetooth OFF)

20 hours at 25 °C (77 °F)

Device run time is reduced nominally by 10% with Bluetooth enabled and nominally by 15% with the Backlight configured to always on. If both Bluetooth and the backlight are on the nominal runtime reduction will be 25%.

Charging time

£ 4 hours

The maximum safe area charging voltage Um = 6.7 VDC

Warm up time

2 min

Temperature range

14 to 104 °F (-10 to 40 °C) Normal operating range

-40 to 140 °F (-40 to 60 °C) Extended operating range

50 to 95 °F (10 to 35 °C) While charging battery

-40 to +140 °F (-40 to 60 °C) Intrinsic safety

ambient temperature range (ATEX, IEC)

-40 to +129 °F (-40 to 54 °C) Intrinsic safety ambient temperature range (CSA, ETL)

Humidity range

15 % – 90 % relative humidity, non-condensing,

5 % – 95 % RH intermittent

Atmospheric pressure range

800 to 1200 mbar

Ingress
protection

IP 68 (2 meters for 45 minutes)

Measuring
methods

Combustible gases: Catalytic sensor

Oxygen: Electrochemical sensor

Toxic gases: Electrochemical sensor

 

Combustible

O2*

CO

H2S

Measuring range

0-100% LEL

0-5.00% Vol.CH4

0-30% Vol.

0-1999 ppm

0-1999 mg/m3

0-200 ppm

0-284 mg/m³

H2S-LC

NO2

CO-H2

SO2

0-100 ppm

0-50 ppm

0-1999 ppm

0-20 ppm

* Certified for 0 - 25 vol.% O2

The technical and performance specifications for the specialized EX-H and EX-M sensor are the same as for the standard EX sensor.

 

The ppm to mg/m³ conversion is calculated at 20° C (68 °F) and at atmospheric pressure.