Troubleshooting
The ALTAIR Single Gas Detector will operate reliably when handled properly. If the instrument becomes inoperative, follow the Troubleshooting Guidelines in Table 2 ; these represent the most likely causes of a problem. You may return inoperative instruments that are under warranty to MSA:
MSA North America Repair and Service Department
1000 Cranberry Woods Drive
Cranberry Township, PA 16066-5207
1-800-MSA-INST
To contact MSA International, please call:
1-412-967-3000 or 1-800-MSA-7777
WARNING!
Repair or alteration of the ALTAIR Single Gas Detector, beyond the procedures described in this manual or by anyone other than a person authorized by MSA, could cause the instrument to fail to perform properly. Use only genuine MSA replacement parts when performing any maintenance procedures described in this manual. Substitution of components can seriously impair instrument performance, alter intrinsic safety characteristics or void agency approvals.
Failure to follow this warning can result in serious personal injury or death.
The instrument displays an error code if it detects a problem during startup or operation. See Table 2 for a brief description of the error and proper corrective action.
Table 2 Troubleshooting Guidelines
Problem | Description | Action |
---|---|---|
Display Toggles Between: | ||
TMP/ ERR | Temperature out of range | Remove from service. Contact MSA during warranty period. |
AD/ ERR | Sensor feedback error | Remove from service. Contact MSA during warranty period. |
EE/ ERR | EEPROM inoperative | Remove from service. Contact MSA during warranty period. |
MEM/ RST | EEPROM Data Error |
Calibrate instrument. Reconfigure any custom settings (alarm setpoints, datalog, etc.) Remove from service. Contact MSA during warranty period. |
PRG/ ERR | Program Memory inoperative | Remove from service. Contact MSA during warranty period. |
RAM/ ERR | RAM inoperative | Remove from service. Contact MSA during warranty period. |
TMR/ ERR | Time or Clock Error | Remove from service. Contact MSA during warranty period. |
BTN/ ERR PWR/ ERR |
Button error (stuck down) Unexpected Power Loss Error |
Remove from service. Contact MSA during warranty period. Remove from service. Contact MSA during warranty period. |
LED/ ERR | LED inoperative | Remove from service. Contact MSA during warranty period. |
VIB/ ERR alarm | Vibrator inoperative | Remove from service. Contact MSA during warranty period. |
UNK/ ERR | Unknown Error | Remove from service. Contact MSA during warranty period. |
UND/ ERR | Sensor under range | Calibrate instrument. If calibration does not correct this error, remove from service. |
![]() |
Low battery warning indicator (no alarm) | Remove from service. Contact MSA during warranty period. |
![]() |
Low battery Alarm indicator (horn sounds, LEDs activate) | Remove from service. Contact MSA during warranty period. |
SNS/ ERR | Sensor Error | Remove from service. Contact MSA during warranty period. |