Preparing Cylinders for Use
For remote connections, make sure the dovetail bracket is attached to the cylinder before use. If the dovetail is not available, do the following:
|
|
|
|
P/N |
Cylinder |
NIOSH Service Life Rating |
Pressure |
Retainer Type |
Retainer Kit P/N |
|
807587 |
H-30 Carbon |
30 minutes |
4500 psig |
Type 2 |
10158389 |
|
807570 |
H-45 Carbon |
45 minutes |
4500 psig |
Type 4 |
10158401 |
|
10035644 |
H-45 LP Carbon |
45 minutes |
4500 psig |
Type 3 |
10158390 |
|
807588 |
H-60 Carbon |
60 minutes |
4500 psig |
Type 5 |
10158402 |
|
|
NOTE: For Snap Retainers, align top snap first and rotate bottom snap into position. |
|||||||||
|
|
NOTE: For Snap Retainers, visually inspect retainer snaps for full engagement as shown. |
|||||||||
|
|
|
WARNING!
Snap-fit cylinder valve retainer buttons is not compatible with bolted cylinder valve retainers.
Failure to follow this warning can result in serious personal injury or death.