Ordering Information

Replacement Parts

See Table 19 for replacement sensor kits. To obtain a replacement sensor, address the order or inquiry to:

General Monitors

16782 Von Karman Ave, Unit 14

Irvine, CA 92606

or call, toll-free, 1-800-446-4872.

Inquiries can also be e-mailed to info.gm@msasafety.com.

WARNING! 

Use only genuine MSA replacement parts when performing any maintenance procedures provided in this manual. Failure to do so may seriously impair sensor and gas monitoring performance, alter flameproof/explosionproof characteristics or void agency approvals. Failure to follow this warning could cause the product to fail to perform as designed and persons who rely on this product for their safety could sustain serious personal injury or loss of life.

Repair or alteration of the S5000 Gas Monitor, beyond the scope of the maintenance procedures provided in this manual or by anyone other than authorized MSA service personnel, could cause the product to fail to perform as designed and persons who rely on this product for their safety could sustain serious personal injury or loss of life.

Failure to follow these warnings can result in serious personal injury or death.

Table 19 Replacement Parts

Type

Description

P/N

PCBA Assemblies

S5000-PCB

Sensor Body, XCell

A-5K-SENS

Sensors, XCell

A-5K-SENS

Sensor Guard, XCell

Sensor Guard Assembly, S5000

10177624

Sensor Guard, ULTIMA XIR PLUS

REPLACEMENT SENSOR GUARD FOR XIR PLUS SENSORS

10184684

Sensor Guard, IR400

Sensor Guard, IR400, with Screen

32545-1

Sensors, Passive

CB 0-100% LEL (C04 – Screened, Div Approvals)

CB 0-20% LEL (C10 – Sintered, Zone Approvals)

CB 0-100% LEL (C11 – Sintered, Zone Approvals)

10058-1

11159-8

11159-1

MOS 0-100ppm (M04 – Screened, Div Approvals)

MOS 0-100ppm (M14 – Sintered, Zone Approvals)

50448-1

51457-1

MOS 0-50ppm (M05 – Screened, Div Approvals)

MOS 0-50ppm (M15 – Sintered, Zone Approvals)

50448-5

51457-5

MOS 0-20ppm (M06 – Screened, Div Approvals)

MOS 0-20ppm (M16 – Sintered, Zone Approvals)

50448-9

51457-9

Sensor, IR4001

Methane, NFPA

IR400-0-01-2-2-0-1-0

Propane, NFPA

IR400-0-02-2-2-0-1-0

Hexane, NFPA IR400-0-04-2-2-0-1-0
Pentane, NFPA IR400-0-05-2-2-0-1-0
Ethylene, NFPA IR400-0-06-2-2-0-1-0
Butane, NFPA IR400-0-07-2-2-0-1-0
Ethane, NFPA IR400-0-08-2-2-0-1-0

Methane, IECEx

IR400-0-13-2-2-0-1-0

Propane, IECEx

IR400-0-14-2-2-0-1-0

Hexane, IECEx IR400-0-15-2-2-0-1-0
Pentane, IECEx IR400-0-16-2-2-0-1-0
Butane, IECEx IR400-0-17-2-2-0-1-0
Ethane, IECEx IR400-0-18-2-2-0-1-0
Ethylene, IECEx IR400-0-22-2-2-0-1-0
     
   
   
   
   

Duct Mount Kit

Duct mount kit, rectangular

10176947

Duct mount kit, round, small,

(12"-20" / 305-508 mm diameter)

10179124

Duct mount kit, round, large,

(20"-40" / 508-1016 mm diameter)

10179321

Calibration Kit (XCell)

CALKIT1

CALKIT2

CALKIT3

CALKIT4

Pipe Mount Kit, Universal

Pipe Mount, X5000/S5000

10176946

Junction Box

Junction Box, SST, IIB + H2

Junction Box, SST, IIC

324240-1

324240-3

JB5000 Junction Box

3/4" NPT

M25

3/4" NPT FM Approved

M25, FM Approved

10213879

10213893

10213892

10213896

Calibration Cap, XCell

Calibration Cap, X5000/S5000, packaged

10181450

Calibration Cap, XIR PLUS

CALIBRATION CAP, ULTIMA XIR PLUS, PCKGD

10181461

Calibration Cap, IR400

Calibration Cap, IR400 packaged

1400270-2

Sun Shield

Sunshield, X5000/S5000

10180254

1- Only IR Sensor P/Ns shown can be used with the S5000.

For position of labels, see   Label Overview

The following accessories have been validated for use when installed in accordance with the instructions in this manual:

Accessory

Validation Method

Calibration Kit CSA & FM Approvals
Junction Box CSA & FM Approvals
JB5000 Junction Box CSA & FM Approvals
Calibration Cap (XCell, IR400) CSA & FM Approvals
Wireless HART CSA & FM Approvals