SafeSwap®
The ULTIMA X5000 comes with patented SafeSwap technology, which allows users to change or replace XCell sensors without needing to power down the instrument. For added convenience, the ULTIMA X5000 comes with Swap Delay enabled by default; a feature that gives users a 2 minute window to change sensors without triggering a fault condition. For more information on SafeSwap and Swap Delay, see Setting.
WARNING!
|
•
|
As part of the product certification, it was verified that optional communication functions of this gas detection instrument while operating at the maximum transaction rate do not adversely affect the gas detection operation and functions of the instrument. The product certification, however, does not include or imply approval of the SafeSwap feature, communications protocol or functions provided by the software of this instrument or of the communications apparatus and software connected to this instrument. |
|
•
|
Follow the warnings below when removing or replacing sensors. Reference Component Overview for component overview. |
|
○
|
Never remove or replace a sensor body assembly or an Ultima XIR Plus while under power or when explosive hazards are present. |
|
○
|
Confirm that the area is free of explosive hazards before removing or replacing an XCell Sensor under power. |
|
○
|
To remove an XCell Sensor, unscrew XCell Sensor three full turns, wait 10 seconds, and then remove the XCell Sensor completely. |
Failure to follow this warning can result in serious personal injury or death.